Archive for freon

Why’s My Coil Freezing?

Wednesday, June 23rd, 2010

Well, it’s been hot lately in Louisville. Real hot.  Certified Comfort has been running full speed six days per week.  My running and training schedule has been put on hold. Good chance your air conditioner has been running hard, too.

Some of you have experienced a frozen coil. The big line between the indoor and outdoor units is covered with ice. If you removed the coil panel, you would see a big blog of ice there as well. Next step is a big puddle of water under the furnace when you stop the unit from running.

So, what causes a frozen coil? Two things primarily cause it: low load and low refrigerant (R-22, R-410a, Freon, Puron, etc.) charge.

Low load. What is that? Well, it’s usually an extremely dirty super high efficient allergy preventing cat hair catching filter that was just changed six months ago. Yep. My favorite. 3M filters. Paul Harvey and Rush promote some nice near-cardboard dense filters, too.

Seriously, I’m not a fan of the high dollar 1″ thick filters. Very few duct systems are designed to handle the pressure drop of the filter. This high pressure drop causes low air flow across the indoor coil. In turn, this makes for a very cold coil. When then filter loads and gets plugged, the airflow can be reduced to a point that the coil temperature is less than 32°F. With a coil that cold, the moisture in the air freezes on the coil surface. If the system runs long enough, you will have a block of ice.

Side note: unless you have an EAC or 5″ media filter, you really only need the cheapo blue filters. Change them monthly when you get your LG&E utility bill. Buy them by the case at your favorite big box store.

The other cause: low refrigerant charge. Now, you may be thinking “Rob when the refrigerant charge is low, the house gets hot. How can this possibly freeze the coil?” Well, here’s the answer.

Low refrigerant charge reduces the pressures of the indoor coil. The lower pressure corresponds to a lower temperature of the refrigerant as it enters the coil. The freezing process starts there. As the system runs and runs and runs, the ice builds and builds. It does take some time to build this ice block.

So, what causes a low charge? Two choices again: a leak or improper charge. Refrigerant should never need to be added to a system unless it wasn’t charged properly at installation.  All systems come charged from the factory with enough refrigerant for a 15′ lineset (the copper pipes between the units). The installing contractor has to add a certain amount of refrigerant for each foot of copper. If not, you’ll get a frozen coil when the unit runs long and hard in the first heat wave.

Well, I hope that you now understand a little better about the causes of a frozen evaporator (indoor) coil. If you have any questions, feel free to ask. Love to help you with questions even if I’m not working for you at this time.

I need some Freon again.

Thursday, May 6th, 2010

Far too frequently, we receive the call from our Louisville customers requesting more freon.  Hmm. Not good.  Air conditioning systems are sealed systems. They shouldn’t need a shot of ‘freon’ every year to keep it cooling.

“What’s the big deal? Just fill ‘er up.”  Well, it is a big deal when you look at all the problems caused by leaking HVAC systems.

The first issues deal with detrimental effects on the system longevity.  Refrigerant (Freon, R-22, R-410a) circulates oil through the system. If you’re low on refrigerant, oil isn’t returned properly to the compressor.  Bearings don’t get lubricated. Compressor life is shortened. You pay more money.

Refrigerant is also the cooling medium for the compressor.  Say what? Yes, really. The refrigerant passes across the compressor windings to keep it cooled. Compressor runs hot. Windings fail. You pay more money for a replacement compressor or a new system.

The second issues deal with ineffective system performance.  As the refrigerant leaks from your system, the indoor coil runs warmer and is unable to remove as much heat from the air. This makes the system have to run longer. Running longer results in higher utility bills. Eventually, the system won’t be able to remove enough heat to maintain set point, and you’ll be calling Certified Comfort again.

The other part of the performance issue is moisture removal. With a warmer coil, you are not sufficiently reducing the dew point of the air. With a higher dew point, more moisture remains in the air being returned to your rooms. Higher humidity levels in the home result in discomfort and you lowering the thermostat set point. The system runs even longer and you pay more money to the utility.

So, before you call for that ‘shot of freon’ consider the long term effects on your wallet and comfort. The wise investment is to let Certified Comfort find the leak and repair it.

Comments (1)